PHYSICAL PROPERTIES AEROCEL TEST METHOD**
CELL STRUCTURE CLOSED CELL
ASTM D 1667
DENSITY Lbs/ft3 (am/cm3) 3/6 Lbs/ft3
THERMAL
CONDUCTIVITY
BTU.in/ft.2hr. °F
Mean
temp.
-40°F
(-20°C)
32°F
(0°C)
75°F
(24°C)
90°F
(32°C)
104°F
(40°C)
ASTM C177
JIS A 1412
K-value 0.22 0.23 0.25 0.26 0.27
SERVICE TEMP **** -70°F to 257°F
-57°C to +125°C
AEROCEL becomes hard at -57°C
but can be used even at -200°C
U.V. Weather Resistance Excellent ASTM G-23
Ozone Resistance No cracking ASTM D 1171
Water Vapor Permeability 0.10 perm-in (0.15 x 10-12) ASTM C355
Water Absorbtion (weight %) 0.2% ASTM C 209
Flammability,
Smoke Density
Class V 0 UL-94
25/50 ASTM E84
Self extinguishing ASTM D 635
Corrosion of copper, stainless Non corrosive DIN 1998
Nitrosamine Contents Not detected U.S. FDA
Flexibility excellent